Terror Screen SR3 - LPS1175 SR3 Security Shutter

LPS1175 SR3 British manufactured Security roller shutters

Security Rating 3 is classified as medium commercial risk. SR3 has significant increase in security grade with the commensurate increase in weight and strength. The products are tested and provide resistance to tools in Category A & B (as specified for SR2) plus C (below). The tools of this category is for deliberate forced entry of well-protected premises using bodily physical force and a wide selection of attack options.

ATTACK TIME

The maximum attack time is 5 minutes. The maximum test duration is 20 Minutes

TOOLS CATEGORY A, B PLUS C

Axe, Battery, Bolt cutter, Brick bolster, Cold Chisel, Crowbar, Drill, Fluorocarbon based freeze spray, Gas torch, Hacksaw, Hammer, Pad saw, Scissor jack, Wood chisel

LOCK/HARDWARE STANDARD

BS EN 1303 class 4 (Building hardware. Cylinders for locks. Requirements and test methods.

FIXING

Brickwork/concrete blockwork, or structural steelwork

If you’d like to speak to us about how we can help you solve logistical challenges with a completely tailored high-speed door solution, please contact us today on +44 (0) 191 214 0404

Colour Options

Optional plastisol coating on the laths and optional powder coating of guides and bottom rail and any other associated parts Standard RAL colours

Size Options
  • Up to 9m high
  • Up to 9m wide
Speed Options
  • Standard opening – 0.15m sec
  • Standard closing – 0.15m sec

Features & Benefits

  • Attack Prevention
  • Security performance
  • Asset protection
  • Public Safety
  • Unauthorised access restriction
  • Insurance compliance
  • Reduced risk of crime

What Hart Has To Offer

1 year warranty
as standard

CE/UKCA mark

Designed and
manufactured in UK

LPCB approved

Design Options

  • Size: Custom- size up to 9000 mm
  • Various locking options available, from simple pin locking to fully automatic operation
  • Choice of colours and finish
  • Lock status signal options
  • Hood covers
  • Choice of operators
  • Infills and Flashings

See NBS Specification

Applications

  • Banks
  • Military Installations
  • Government buildings
  • Museums
  • Nuclear Facilities
  • Detention Centres
  • Prisons
  • Chemical Industries
  • Airports
  • Data Centres
  • Hazardous Environments
  • Security Risk Control Buildings
  • Warehouses

Related Case Studies

Manufactured to International Standards


Motor

Depending on door size the motor drive is constructed using either Safedrive direct drive or via chain drive and reduction gearing supported via a safety brake. Very large sizes may also have internal counterbalance springs to reduce operating loads and minimise the drive requirements.

ENGINEERING

Size

Doors are available from 1.2 metre wide to 9 metres wide and up to 9 metres high. All doors are made to measure to specific requirements. For a higher security rating or extreme wind conditions we recommend the SR4 Terror Screen doors or our unique Typhoon security shutter.

Curtain

Roller shutter door electrically operated utilising a steel twin skin door curtain of twin interlocking optionally insulated roller shutter section. The construction of the door curtain is 35Kg’s per square meter and it runs within side guides of fabricated steel

Locking

  • Manually operated slip bolts on the bottom rail or pin locks on the guide, manually interlocked to the control panel to prevent accidental operation.
  • Electrically operated by press button when the door is closed
  • Fully automated.
  • Optional Monitoring and signalling of lock status.

Bottom Latch

The door curtain is finished at floor level with a structural bottom beam fabricated from steel and aluminium sections and optionally finished by rubber seal. Available up to 9m without need for locking at the centre of the rail.

Operators

The door can be press button operated or automatically operated. Various levels of safety can be incorporated which are obligatory if automated operation is required, including safe leading edge and or photocells movement sensors Radar, radio and so on. Controls should be mounted at least 1m from the door structure, unless additional features are added

Fixing

Structural opening substrate must be suitably reinforced brickwork/concrete/steelwork as detailed in the standard LPS1175 Issue 7. It is assumed that the substrate onto which the product is fitted provides a resistance to attack at least equivalent to that afforded by the product itself.

PERFORMANCE

Speed

Standard opening Speed: 0.15 m/s
Standard Closing Speed: 0.15 m/s

  • Manufactured under ISO 9001:2015
  • Machinery Directive 2008 26/42/EC
  • BSEN 12453 & BSEN12444 the machinery directive safety in use of power operated doors
  • BSEN 12978 Safety devices for power operated doors
  • BSEN 12625 – requirements for the safe installation and use

Need Technical Advice?

Call us now on +44 (0) 191 214 0404
or click below to get in touch

Make an Enquiry